This automated optical Fiber tensile screening system is ideal for operator skill impartial use in production and laboratory settings. Two basic model designs allow the user to select between a set up for standard linear Proof testing and with additional mandrels for rotary high strength screening.

The linear version is made for production Proof testing with causes up to 22 N. Motorized clamps with carefully developed rubberized inserts ensure that the Sheathing Line is not really damaged inside the screening process while at the same time getting rid of the requirement for an external air supply. Amounts of tugging force, tugging speed and hold time are automated and easily available to the operator from the built in Liquid crystal display touchscreen display control. Data from assessments can be saved and reached using the Universal serial bus dock or Ethernet user interface.

Mandrels the exact same style as in NYFORS’ optical Fiber recoaters can be easily mounted on the Proof tester inside the rotary high strength configuration. The Fiber is wrapped around the two mandrels which assistance it with a unique clamping system. In this way much higher loads can be employed on the Fiber, enabling breaking up strength tests below managed circumstances.

Changeable clamp placement facilitates screening using the greatest force amounts as well as screening of brief Fiber lengths. The compact and light weight style helps make the instrument simple to move around in a laboratory atmosphere and also to integrate in a creation work table in which space reaches a premium. The equipment is really a compact and light-weight instrument ideal for testing the potency of visual materials as much as 30 N. The equipment is created to fulfill all sorts of programs in which a strength test must be performed.

The device is designed using the consumer in mind. The SZ Stranding Line is definitely placed in the carefully guided linear clamps, as well as the screening begins automatically with a “One Touch” go button. The built in microprocessor controls all of the important parameters like pulling force, tugging speed and hold time. This permits for any totally managed test each time.

The machine can be linked to another PC, which allows usage of all programmable parameters and settings. The device is tailored to face-alone use or the incorporation into various subsystems. The equipment comes with an extensive capability of signing and saving information including tugging force, pulling speed and Fiber diameter along with other parameters.

Two recoat injector designs can be purchased. The PTR307 uses an automated pump to inject the recoat material. The amount of materials dispensed by the automatic injector is controlled by hand using the top-mounted “Inject” switch or programmed to the machine utilizing the tablet controller. The PTR307B includes a manual recoat injection program that will require the consumer to manually distribute the recoat material to the mold cavity; another one injector for your PTR307B recoater is accessible listed below. Make sure you note that this automatic injector is just compatible with high-directory recoat materials, as the handbook injector works with both reduced- and- directory recoat material; both of them are sold individually listed below. Please contact Tech Assistance for more information.

he handbook injector can be installed to suitable Fiber recoaters via the 4-40 screws on the recoater real estate (see picture to the right). Utilize a 3/32″ hex key to secure the injector before use. To connect the PTRRRM to the recoater mold, tighten up the connector after the green plastic material tubing, then release with a 1/4 choose permit rotation.

The injector is equipped with a distribution valve and 2-place choice lever for directing the flow of recoat materials. A knurled dispensing attach with the inner plunger behaves as a syringe for the recoat material. To fill the syringe, point the lever downward (i.e., towards the recoat container), then spin the knurled dispensing screw counterclockwise till it spins freely to fill up the syringe (demonstrated inside the photo towards the right). Then, to inject the recoat materials into the mold, point the handle horizontally (i.e., facing qyjflh knurled attach) and rotate the attach clockwise till nearby the finish from the journey range is reached. Avoid bottoming the dispenser since this may harm the internal plunger; also take care when re-interesting the threads in order to avoid go across threading the dispensing attach. A number of fill/inject actions may be needed till air is displaced in the system. Use lens cells as well as an acetone or alcohol cleansing solution to gather Secondary Coating Line materials that flows from your mold.

Fiber Drawing Machine – Why Is This Important..

We are using cookies on our website

Please confirm, if you accept our tracking cookies. You can also decline the tracking, so you can continue to visit our website without any data sent to third party services.